{"product_id":"wall-mounted-heat-recovery-unit-mitsubishi-electric-lossnay-vl-80u5-e-with-pull-switch","title":"Unità di recupero calore da parete Mitsubishi Electric Lossnay VL-80U5-E (interruttore a tirante)","description":"\u003ch6 style=\"text-align: center;\"\u003eDescription\u003cbr\u003e\n\u003c\/h6\u003e\n\u003cp\u003eMitsubishi Electric Lossnay \u003cstrong\u003eVL-80U5-E\u003c\/strong\u003e is a single-room ventilation unit with heat recovery. It delivers fresh air in and extracts stale air simultaneously through the Lossnay heat-exchange core, reducing heat loss and improving indoor air quality. This model features a \u003cstrong\u003epull-cord control\u003c\/strong\u003e for quick mode changes, quiet operation, and low power draw. This device is ideal for apartments, houses, home offices and small classrooms where ductwork is not feasible. \u003c\/p\u003e\n\u003ch3\u003eKey differences at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePull-cord control\u003c\/strong\u003e with three positions: HI (Fast), LO (Slow) and OFF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAirflow\u003c\/strong\u003e up to \u003cstrong\u003e80 m³\/h\u003c\/strong\u003e (HI) and \u003cstrong\u003e49 m³\/h\u003c\/strong\u003e (LO).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow sound\u003c\/strong\u003e: ~\u003cstrong\u003e26 dB\u003c\/strong\u003e (LO) \/ ~\u003cstrong\u003e37 dB\u003c\/strong\u003e (HI).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat-exchange efficiency\u003c\/strong\u003e: ~\u003cstrong\u003e70 %\u003c\/strong\u003e (LO) \/ ~\u003cstrong\u003e62 %\u003c\/strong\u003e (HI).\u003c\/li\u003e\n\u003cli\u003e\u003cem\u003e\u003cstrong\u003eDual filtration\u003c\/strong\u003e with optional high-performance outdoor filter (P-80HF-E) to reduce insect ingress; standard replacement filter P-80F-E.\u003c\/em\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat does a heat recovery unit solve?\u003c\/h3\u003e\n\u003cp\u003eIn rooms with inadequate ventilation, typical issues arise:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eMoisture build-up and window condensation;\u003c\/li\u003e\n\u003cli\u003eMold and mildew formation, allergy risks;\u003c\/li\u003e\n\u003cli\u003eElevated CO₂ that harms well-being and focus;\u003c\/li\u003e\n\u003cli\u003eDamage to finishes, furnishings and electronics.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eThe Lossnay VL-80U5-E:\u003c\/strong\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eProvides continuous air exchange without opening windows;\u003c\/li\u003e\n\u003cli\u003eUses a heat-exchange core to temper incoming air using indoor air energy;\u003c\/li\u003e\n\u003cli\u003eReduces particles with integrated filters for supply and extract air;\u003c\/li\u003e\n\u003cli\u003eImproves comfort, health and productivity for occupants.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eWhere to use this device?\u003c\/h3\u003e\n\u003cp\u003ePerfect for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eApartments and private homes;\u003c\/li\u003e\n\u003cli\u003eHome offices, studios and small workspaces;\u003c\/li\u003e\n\u003cli\u003eEducational rooms and small meeting rooms without central ventilation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNote: For bedrooms, install at a distance to avoid perceiving airflow\/noise in very quiet environments.\u003c\/p\u003e\n\u003ch3\u003eFeatures of Mitsubishi Electric Lossnay VL-80U5-E\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePull-cord operation\u003c\/strong\u003e: quick switching between HI\/LO\/OFF; vertical or horizontal airflow can be adjusted via manual louver; \u003cem\u003edo not pull the cord at an angle\u003c\/em\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnergy efficient\u003c\/strong\u003e heat recovery for tightly sealed homes; low running watts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet\u003c\/strong\u003e running suitable for living spaces; \u003cstrong\u003ewall-mount only\u003c\/strong\u003e (not for ceiling mount).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeather covers\u003c\/strong\u003e (included) must be used in adverse conditions; \u003cstrong\u003estop operation below -10 °C\u003c\/strong\u003e and fit covers to prevent ingress of rain\/snow and protect the core. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation\u003c\/h3\u003e\n\u003cp\u003eThis unit is designed for \u003cstrong\u003ewall installation\u003c\/strong\u003e with an outdoor weather hood. Keep clearances around the unit to avoid blocking inlets\/outlets and to allow service access. Installation should be performed by authorized personnel.\u003c\/p\u003e\n\u003ch3\u003eMaintenance \u0026amp; filters\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eClean outdoor and exhaust filters at least every \u003cstrong\u003e6 months\u003c\/strong\u003e; replace standard filter \u003cstrong\u003eP-80F-E\u003c\/strong\u003e after ~4 washes.\u003c\/li\u003e\n\u003cli\u003eOptional \u003cstrong\u003eP-80HF-E\u003c\/strong\u003e outdoor filter reduces small insects; clean with vacuum, do not use hot water or harsh detergents.\u003c\/li\u003e\n\u003cli\u003eClean the Lossnay core annually with a vacuum only (no water\/chemicals).\u003c\/li\u003e\n\u003cli\u003eReassemble carefully and ensure all hooks are seated.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch6 style=\"text-align: center;\"\u003eTechnical specification\u003cbr\u003e\n\u003c\/h6\u003e\n\u003cdiv class=\"spp-table\"\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003eRecommended room area for one unit\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-value-col\"\u003e\n\u003cdiv class=\"spp-table-value\"\u003e ~50 m² \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-row-group-label-col\"\u003e\n\u003cdiv class=\"spp-table-row-group-label\"\u003eAir Exchange Rates\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003eAir exchange at LO\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-value-col\"\u003e\n\u003cdiv class=\"spp-table-value\"\u003e49 m³\/h\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003eAir exchange at HI\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-value-col\"\u003e\n\u003cdiv class=\"spp-table-value\"\u003e80 m³\/h\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003eRecovery efficiency (LO \/ HI)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-value-col\"\u003e\n\u003cdiv class=\"spp-table-value\"\u003e70 % \/ 62 %\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-row-group-label-col\"\u003e\n\u003cdiv class=\"spp-table-row-group-label\"\u003eOperating Guidance\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003eCold-weather note\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-value-col\"\u003e\n\u003cdiv class=\"spp-table-value\"\u003eStop operation at ≤ −10 °C and fit weather covers; wipe any surface condensation.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-row-group-label-col\"\u003e\n\u003cdiv class=\"spp-table-row-group-label\"\u003eElectrical \u0026amp; Performance\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003ePower consumption (LO \/ HI)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-value-col\"\u003e\n\u003cdiv class=\"spp-table-value\"\u003e15.5 W \/ 28 W\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003eSound pressure (LO \/ HI)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-value-col\"\u003e\n\u003cdiv class=\"spp-table-value\"\u003e26 dB \/ 37 dB\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003eVoltage (V \/ Phase \/ Hz)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-value-col\"\u003e\n\u003cdiv class=\"spp-table-value\"\u003e230 V \/ 1 \/ 50 Hz\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-row-group-label-col\"\u003e\n\u003cdiv class=\"spp-table-row-group-label\"\u003eDimensions \u0026amp; Weight\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003eModule dimensions (W×H×D)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-value-col\"\u003e\n\u003cdiv class=\"spp-table-value\"\u003e620 × 265 × 200 mm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003eWall core hole diameter\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-value-col\"\u003e\n\u003cdiv class=\"spp-table-value\"\u003eØ90 mm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003eDuct size (outer diameter)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-value-col\"\u003e\n\u003cdiv class=\"spp-table-value\"\u003e2 x Ø75 mm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003eWeight\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-value-col\"\u003e\n\u003cdiv class=\"spp-table-value\"\u003e8.8 kg\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-row-group-label-col\"\u003e\n\u003cdiv class=\"spp-table-row-group-label\"\u003eControls \u0026amp; Accessories\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003eControl\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-value-col\"\u003e\n\u003cdiv class=\"spp-table-value\"\u003ePull-cord (HI \/ LO \/ OFF)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003eAirflow direction\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-value-col\"\u003e\n\u003cdiv class=\"spp-table-value\"\u003eManual louver (vertical\/horizontal)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003eWeather covers\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-value-col\"\u003e\n\u003cdiv class=\"spp-table-value\"\u003eUse during adverse weather \/ cold conditions\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003eFilters\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-value-col\"\u003e\n\u003cdiv class=\"spp-table-value\"\u003eStandard P-80F-E (replace after ~4 washes); optional P-80HF-E for outdoor intake\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003eEuropean Quality Certificate CE\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spp-table-row\"\u003e\n\u003cdiv class=\"spp-table-label-col\"\u003e\n\u003cdiv class=\"spp-table-label\"\u003e2 year warranty\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Mitsubishi Electric","offers":[{"title":"Default Title","offer_id":52098327740762,"sku":"VL-80U5-E","price":557.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0607\/5416\/5992\/files\/Mitsubishi-Electric-Lossnay-VL-80U5-E-sienas-rekuperators.webp?v=1756994776","url":"https:\/\/airo2.it\/products\/unita-di-recupero-calore-da-parete-mitsubishi-electric-lossnay-vl-80u5-e-con-interruttore-a-tirante","provider":"Māja elpo","version":"1.0","type":"link"}